Fire Hall Signals
Series II Controller
The Novax Fire Hall Signal Controller provides direct control of the signal lights at the fire hall and at any nearby intersections for safe, rapid deployment of fire trucks.
Series II Controller (Fire Hall Signals)
• Operating Voltage: 115VAC ± 20VAC
• Operating Power: 5 Watts (No Output Loads Operating)
• Operating Temperature: -40 °C to +85 °C
• Storage Temperature: -40 °C to +85 °C
• Faceplate Displays: Five 7-Segment (Red) LED’s (c/w “Sleep Mode” -shuts Display OFF when Not in Use)
• Input Displays: Three (Red) LED’s (3 for Inputs)
• Output Displays: Six (Red) LED’s (6 for Outputs)
• Keypad: MODE, UP & DOWN Switches for Controller Setup
• Test Switches: Three Push Input Test Switches (on Panel)
• DC Inputs (External): Two Normally Open - (N.O.) Dry Contact Closure Optically Isolated, 24VDC, 0.2 A (Inputs 1 & 2)
• AC Inputs (External): One Normally Open - (N.O.) Dry Contact Closure Optically Isolated, 115VAC, 0.2 A (Input 3)
• Outputs: Six 115 VAC, Solid State & Zero-crossing. Rated for Tungsten Lamps. Fused @ 10 Amperes each
• Terminal Barriers: Accepts up to 10 AWG Wire
• Interval Timers: Nine User-Adjustable (0 - 250 Seconds)
- Start Delay Time
- Flashing Yellow Time
- Steady Yellow Time
- Steady / Alternating Flashing Red Time
- Extend ‘1’ Time
- Extend ‘2’ Time
- Extend ‘3’ Time
- Preemption ‘1’ Delay Time
- Preemption ‘2’ Delay Time
- Minimum Vehicle Passage Time
• Countdown Timer: Runs concurrently with the Interval timers
• Part #:ELA515